Diaphragm multi-function pump control valve
- Products
- Ball valve
- Butterfly valve
- Gate valve
- Globe Valve
- Check valve
- Anticorrosive valve
- Forged steel valve
- Regulating valve
- Hydraulic control valve
- Power station valve
- Drain valve
- Bellows valve
- Metallurgical valve
- Flame arrester and breathing valve
- Solenoid valve
- Needle valve
- Copper valve
- Ceramic valve
- Oil field valve
- Safety valve
- Actuator series
Nominal diameter: DN40 ~ 1600mm
Nominal: PN1.0 ~ 2.5MPa
Suitable medium: water, oil, water, sewage
Temperature: 0 ~ 80 ℃
Flange Standard: GB / T17241.6, GB / T9113
Test standards: GB / T13927, API598
First, the multi-function pump control valve Structural features
Multi-function pump control valve by the main valve and control valve
and take over the system, the valve body with a DC valve, the main valve
control chamber for the diaphragm or piston double control room
structure, Control room than the general increase of a hydraulic control
valve, an increase of the main valve control functions, to achieve a
slow opening of the pump outlet, fully open, slow closing, cut-off and
other multi-functional control, a valve, a regulation of the pump
Multi-outlet control.
The product takes over the control system using the valve control, by
setting the opening of the control valve can be easily achieved the need
for various control parameters, such as the opening of the main valve
speed, slow closing speed and so on.
Second, the principle of multi-function pump control valve
When the pump starts, the pressure acting on the main valve plate
below the control room and the lower chamber, the pressure to open the
main valve, the control room after the water chamber slowly through the
control valve B To the outlet, the main valve slowly open. Setting the
opening of the control valve results in a proper main valve opening
speed. When the pump stops working, the water pressure at the inlet
decreases rapidly, most of the opening is quickly closed under dead
weight and spring pressure to prevent the water from flowing back. The
remaining opening degree is controlled by the combination of the water
pressure in the upper chamber and the water pressure in the lower
chamber Slowly shut down, slow down the closure of the formation of a
buffer to prevent the pressure surge.
Set the control valve A, B opening and opening ratio can be a suitable valve opening and closing speed.
Third, the multi-function pump control valve working characteristics
1, to prevent the water hammer effect is good, the slow open, check
the closure speed, slow closing, etc. to eliminate water hammer
technology integration, to prevent the pump does not hammer and stop the
pump back and water hammer Water supply pipe and pump damage.
2, easy to operate, no need to reprovision the valve with electronic
control system, the valve with the pump to open and stop automatically
and in order to complete the control function. By setting the valve
opening degree can get the appropriate control parameters.
3, the valve body with a full channel, DC, streamlined design. Small hydraulic loss, energy-saving effect.
four,Multifunctional pump control valve function and purpose
The valve is installed at the pump outlet, the order to achieve a slow
opening, full open, closed fast, slow closure and other functions.
This product is used in high-rise building water supply system and
other water supply system of the pump outlet pipeline, to prevent and
reduce the water hammer on the pipeline when the water hammer start and
stop to prevent water back to protect the pump to maintain pipeline
safety.
Five, multi-function pump control valve main technical parameters
Nominal pressure (Mpa) |
Shell test pressure (MPa) |
Seal test pressure (MPa) |
Regulating range (MPa) |
Slow closing time (S) |
Minimum working pressure (MPa) |
Suitable media |
Medium temperature (℃) |
1.0 |
1.5 |
1.1 |
0.09-0.8 |
3-60 |
≥0.07 |
water |
0-80 |
Sixth, multi-function pump control valve main parts and materials
Part Name |
Parts and materials |
Body valve cover |
WCB |
Valve seat disc |
Copper alloy / 2Cr13 |
O-ring seals |
Nitrile rubber |
Valve stem |
2Cr13 |
spring |
50CrVA |
Cylinder piston (piston type) |
2Cr13 |
Diaphragm (diaphragm type) |
Cloth fabric nitrile rubber |
Regulating valve ball valve |
Copper alloy |
filter |
stainless steel |
Seven, multi-function pump control valve parts list:
1, the main valve 2, the flow control valve 3, the filter
Eight, multi-function pump control valve connection size
DN |
L |
H |
D (mm) |
D1 (mm) |
b (mm) |
D2 (mm) |
n-Φd |
||||||||||
mm |
mm |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
PN1.0 |
PN1.6 |
PN2.5 |
|
40 |
240 |
270 |
150 |
150 |
150 |
110 |
110 |
110 |
18 |
18 |
18 |
88 |
88 |
84 |
4-17.5 |
4-17.5 |
4-18 |
50 |
240 |
270 |
165 |
165 |
165 |
125 |
125 |
125 |
20 |
20 |
20 |
102 |
102 |
99 |
4-17.5 |
4-17.5 |
4-18 |
65 |
270 |
340 |
185 |
185 |
185 |
145 |
145 |
145 |
20 |
20 |
22 |
122 |
122 |
118 |
4-17.5 |
4-17.5 |
8-18 |
80 |
300 |
400 |
200 |
200 |
200 |
160 |
160 |
160 |
22 |
22 |
24 |
133 |
133 |
132 |
8-17.5 |
8-17.5 |
8-18 |
100 |
350 |
440 |
220 |
220 |
235 |
180 |
180 |
190 |
24 |
24 |
24 |
158 |
158 |
156 |
8-17.5 |
8-17.5 |
8-22 |
125 |
400 |
460 |
250 |
250 |
270 |
210 |
210 |
220 |
26 |
26 |
26 |
184 |
184 |
184 |
8-17.5 |
8-17.5 |
8-26 |
150 |
480 |
500 |
285 |
285 |
300 |
240 |
240 |
250 |
26 |
26 |
28 |
212 |
212 |
211 |
8-22 |
8-22 |
8-26 |
200 |
500 |
640 |
340 |
340 |
360 |
295 |
295 |
310 |
28 |
30 |
30 |
268 |
268 |
274 |
8-22 |
12-22 |
12-26 |
250 |
605 |
690 |
395 |
405 |
425 |
350 |
355 |
370 |
28 |
32 |
32 |
320 |
320 |
330 |
12-22 |
12-26 |
12-30 |
300 |
700 |
820 |
445 |
460 |
485 |
400 |
410 |
430 |
28 |
32 |
34 |
370 |
370 |
389 |
12-22 |
12-26 |
16-30 |
350 |
800 |
950 |
505 |
520 |
555 |
460 |
470 |
490 |
30 |
36 |
38 |
430 |
430 |
448 |
16-22 |
16-26 |
16-33 |
400 |
900 |
1400 |
565 |
580 |
620 |
515 |
525 |
550 |
32 |
38 |
40 |
482 |
482 |
503 |
16-26 |
16-30 |
16-36 |
450 |
1000 |
1580 |
615 |
640 |
670 |
565 |
585 |
600 |
32 |
40 |
42 |
532 |
550 |
548 |
20-26 |
20-30 |
20-36 |
500 |
1100 |
1600 |
670 |
715 |
730 |
620 |
650 |
660 |
34 |
42 |
44 |
585 |
585 |
609 |
20-26 |
20-33 |
20-36 |
600 |
1300 |
1815 |
780 |
840 |
845 |
725 |
770 |
770 |
36 |
48 |
46 |
685 |
685 |
720 |
20-30 |
20-36 |
20-39 |
700 |
1400 |
2040 |
895 |
910 |
960 |
840 |
840 |
845 |
40 |
54 |
50 |
800 |
800 |
820 |
24-30 |
24-36 |
24-42 |
800 |
1500 |
2350 |
1015 |
1025 |
1085 |
950 |
950 |
990 |
44 |
58 |
54 |
905 |
905 |
925 |
24-33 |
24-39 |
24-48 |
900 |
1700 |
2606 |
1115 |
1125 |
1185 |
1050 |
1050 |
1090 |
46 |
62 |
58 |
1005 |
1005 |
1028 |
28-33 |
28-39 |
28-48 |
1000 |
1900 |
2765 |
1230 |
1255 |
1320 |
1160 |
1170 |
1210 |
50 |
66 |
62 |
1110 |
1110 |
1140 |
28-36 |
28-42 |
28-56 |
1200 |
2050 |
2950 |
1455 |
1485 |
1530 |
1380 |
1390 |
1420 |
56 |
52 |
70 |
1330 |
1328 |
1350 |
32-39 |
32-48 |
32-55 |
1400 |
2200 |
3180 |
1675 |
1685 |
1755 |
1590 |
1590 |
1640 |
62 |
58 |
76 |
1530 |
1530 |
1560 |
36-42 |
36-48 |
36-60 |
1600 |
2400 |
3400 |
1915 |
1930 |
1955 |
1820 |
1820 |
1860 |
68 |
64 |
84 |
1750 |
1750 |
1780 |
40-48 |
40-55 |
40-60 |